{"product_id":"netgear-gs752tpp-gestito-l2-l3-l4-gigabit-ethernet-10-100-1000-supporto-power-over-ethernet-poe-grigio-150109","title":"Netgear gs752tpp gestito l2\/l3\/l4 gigabit ethernet (10\/100\/1000) supporto power over ethernet (poe) grigio - 150109","description":"Netgear Switch GS752TPP-300EUS GS752TPP300EUS (GS752TPP-300EUS)   \u003cstyle\u003e                .break_cols {                    display: flex                    \/* align-items: center *\/                    justify-content: space-between                    column-gap: 30px                }                .tableRowHead h3 {                    background: #EEF1FA                    margin: 0                    padding: 5px                    font-size: 16px                    font-weight: 600                }                .table {                    border-radius: 5px                    border: 1px solid #c5c9e2                }                .inner-data {                    display: flex                    align-items: center                    padding: 5px                    justify-content: space-between                }                .spec-column {                    width: 50%                }                .ds_label {                    width: 50%                }                .ds_data {                    width: 50%                }            \u003c\/style\u003e\u003cdiv class=\"container mb-btm\"\u003e\u003cdiv class=\"panel-body break_cols\"\u003e\n\u003cdiv class=\"spec-column\"\u003e\u003cdiv class=\"table\"\u003e\u003cdiv class=\"tableRow\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eCaratteristiche di gestione\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"What switch device has\"\u003eTipo interruttore\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eGestito\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"A network switch is a computer networking device that links networking segments. A switch has different layers\"\u003eLivello del commutatore\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eL2\/L3\/L4\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eIspezione ARP\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eConnettività\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The number of basic switching RJ-45 Ethernet ports (sockets).\"\u003eQuantità di porte RJ-45\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e48\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The type\/category of basic switching RJ-45 Ethernet ports (sockets).\"\u003eTipo di porte RJ-45\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eGigabit Ethernet (10\/100\/1000)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"An SFP (\" small form-factor pluggable transceiver is a transmitter which interfaces network device motherboard in switch\u003eQuantità di moduli SFP installati\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e4\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eQuantità di porte USB Tipo-A\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eCollegamento in rete\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The way in which the network is working\"\u003eStandard di rete\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eIEEE 802.1D, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.3ad, IEEE 802.3x\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003ePercorsi IPv4\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e32\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003ePercorsi IPv6\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e32\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"A Virtual Local Area Network (VLAN) consists of a group of computers and switches that can be physically distributed over different networks and buildings\"\u003eVLAN support\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eNumero di VLA\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e256\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eTrasmissione dati\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The data transfer capacity of the switch per second.\"\u003eCapacità di commutazione\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e104 Gbit\/s\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The MAC address is the 'Media Access Control Address'. It is a unique address given to a network interface controller (NIC) in a device. A MAC address table shows the addresses in a table format.\"\u003eDimensioni tavola MAC\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e16000 voci\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eLatenza (10-100 Mbps)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e9,617 µs\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eLatenza (1 Gbps)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e4,411 µs\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eBuffer di memoria di pacchetto\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e1,5 MB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eSicurezza\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eCaratteristiche DHCP\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eDHCP snooping, DHCPv6 client\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eLista di controllo accesso (ACL)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eVoci IPv4 Access Control List (ACL)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e100\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eFunzioni Multicast\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eSupporto multicast\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eNumero di gruppi multicast filtrati\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e512\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eDesign\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The type of mounting that can position devices in a shelving system (rack).\"\u003eMontaggio rack\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The colour e.g. red\"\u003eColore del prodotto\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eGrigio\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eRedundant fans support\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The quantity of fans (apparatus with rotating blades that creates a current of air for cooling or ventilation).\"\u003eNumero di ventole\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e3 ventola(e)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"spec-column\"\u003e\u003cdiv class=\"table\"\u003e\u003cdiv class=\"tableRow\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003ePrestazione\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"Whether or not a processor is built into the device.\"\u003eProcessore integrato\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The manufacturer that produced the processor.\"\u003eProduttore processore\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eARM\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The model number for the processor in a computer.\"\u003eModello del processore\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eARM Cortex-A55\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"La velocità del processore è espressa. Spesso la velocità dello stesso viene misurata dal manuffatore in Ghz (1 GHz = 1000 MHz). La tassa dell' ' orologio è la tassa fondamentale per giro al secondo(misurato in hertz) alla quale il computer svolge le operazioni base come per esempio l'addizione di numeri.Ci sono inoltre ulteriori fattori che influenzano il tempo di risposta del dispositivo, come ad esempio la capacità della memoria interna.\"\u003eFrequenza del processore\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e800 MHz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"La capacità della memoria misurata in megabyte installata nell' hardware del sistema\"\u003eRAM installata\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e512 MB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eMemoria flash\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e64 MB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The amplitude level of the undesired background noise\"\u003eEmissione acustica\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e39,3 dB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"Modo statistico usato per indicare l'affidabilità del prodotto\/ meccanismo espresso in ore e percentuale per circuiti di lavorazione. Il numero (espresso in ore)non calcola il tempo prima dell'errore della singola unit à\/ meccanismo.\"\u003eTempo medio tra guasti (MTBF)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e1296949 h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eGestione energetica\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"What is providing power for the product e.g. mains electricity.\"\u003eAlimentazione\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eAC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"Ammontare di energia consumata da questo modello espressa in watt, Solitamente i valori emessi dal produttore  corrispondono a valori a dispositivo spento, in stand-by, durante il normale utilizzo e alle sue massime prestazioni\"\u003eConsumi\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e49 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The maximum amount of power used by the device.\"\u003eConsumo energetico (max)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e861 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003ePower over Ethernet (PoE)\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\n\u003cspan title=\"The device supports Power over Ethernet (PoE)\"\u003eSupporto Power over Ethernet (PoE)\u003c\/span\u003e\u003cspan\u003e*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eSì\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eQuantità di porte Power over Ethernet plus (PoE+)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e48\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003ePotenza Power over Ethernet (PoE) per porta\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e760 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eCondizioni ambientali\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The minimum and maximum temperatures at which the product can be safely operated.\"\u003eIntervallo temperatura di funzionamento\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e0 - 50 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The minimum and maximum temperatures at which the product can be safely stored.\"\u003eIntervallo di temperatura\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e-20 - 70 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eRange di umidità di funzionamento\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e0 - 90%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eUmidità\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e0 - 95%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"Il calore misurato in unità di misura inglese per ore, generate dal fornitore di energia\"\u003eDissipazione del calore\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e2944,6 BTU\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eDimensioni e peso\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The measurement or extent of something from side to side.\"\u003eLarghezza\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e440 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"The distance from the front to the back of something.\"\u003eProfondità\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e310 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"Altezza del prodotto\"\u003eAltezza\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e432 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"Il peso del prodotto senza imballaggio (peso netto). Se possibile, il peso netto viene espresso compreso di accessori standard e forniture . Notate che alle volte il produttore interpreta troppo seriamente il peso del prodotto,tralasciando il peso degli accessori e\/o fornimenti .\"\u003ePeso\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003e5,03 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tableRowHead row\"\u003e\u003ch3\u003eCertificati di sicurezza\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"row inner-data\"\u003e\n\u003cdiv class=\"ds_label\"\u003e\u003cspan title=\"\"\u003eCertificazione\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds_data\"\u003eCE, FCC Class A, RCM, ICES Class A, VCCI, KC, BSMI, UKCA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"Senza Marca","offers":[{"title":"Default Title","offer_id":50002358173960,"sku":"SH-1053227","price":1278.93,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/6849\/3576\/files\/ca30b90154cca9558354619be73ad93445e061a3.webp?v=1777867699","url":"https:\/\/www.bricobravo.com\/products\/netgear-gs752tpp-gestito-l2-l3-l4-gigabit-ethernet-10-100-1000-supporto-power-over-ethernet-poe-grigio-150109","provider":"BricoBravo","version":"1.0","type":"link"}